TBML 150 P 60Hz - Burners Baltur

TBML 150 P 60Hz

Code 56555410

Two-stage mixed gas/light oil burners.

  • Two-stage..
  • Mechanical pulverization.
  • Alternative operation.
Technical data
Fuel
Natural Gas
Operation
Two-stage
Minimum Thermal Power (kW) to ErP
550
Maximum Thermal Power (kW) to ErP
1500
Min flow rate (Sm³/H)
58
Max flow rate (Sm³/H)
159
Second Fuel
Light oil
Second Fuel Operation
Two-stage
Second Fuel Min Thermal Power (kW)
550
Second Fuel Max Thermal Power (kW)
1500
Min flow rate (kg/h)
46
Max flow rate (kg/h)
126
Max Viscosity (°E)
1.5
Electric power supply type
AC
No. of Phases
3N
Power Supply Voltage (V)
380
Power Supply Frequency (Hz)
60
Fan Motor Power (kW)
2.6
Weight without packaging (kg)
0
Weight with packaging (kg)
90.1
Width (mm)
1070
Depth (mm)
800
Height (mm)
700
Technical Descriptions
Burner with alternate methane gas/diesel fuel supply, EC approved according to European Directives EN676 and EN267. Two-stage operation.
Gas side burner with low NOx and CO emissions in accordance with European standard EN676: class 2.
Burner with Low NOx and CO emissions on light oil according to European standard EN267:
Regulating combustion air and blast-pipe.
Combustion air intake with throttle damper. Mechanical cam air flow adjustment.
Combustion air intake designed to achieve optimum linearity of the air gate opening.
Fully closing air damper on shutdown to avoid loss of heat through the chimney.
Maintenance facilitated by the possibility of removing the combustion head without having to remove the burner from the boiler.
Sliding boiler coupling flange to adapt the blast-pipe to the various types of boilers.
Easy maintenance thanks to the two-sides hinge which allows the removal of the combustion head without having to remove the burner from the boiler.
CE version gas train is complete with butterfly valve, operation and safety valve with electromagnetic drive, valve tightness control, minimum pressure switch, pressure regulator and gas filter.
Fail proof connectors for burner/gas train connection
Gas train exit: high.
Pump connected to fan motor through electromagnetic clutch.
Fuel supply circuit made of gear pump with pressure adjustment, shut-off valves and safety valve
Manual fuel switching.
Flame detection by means of infrared IRD photocell.
Control panel with display diagram for working mode with indication lights .
Electric control board in light alluminum alloy with IP55 protection rating
7-pole socket for burner electric and thermostatic supply.
4-pole socket for second stage control.
Electrical system with protection rating IP54.
Documents
Public documents
Type summary
Revision
Publish Date
Languages
Technical Sheet
1.0
01/07/2021
Use and maintenance manual
202008
 
Operating range

This product is part of the range TBML P

Discover the entire series
Login
Cookies help us deliver our services. Using these services, you agree to the use of cookies on our part. Info