Support 800 33 55 33
BTG 20 LX 50-60Hz - Burners Baltur

BTG 20 LX 50-60Hz

Code 15100010

Progressive/modulating two-stage gas burners with low polluting emissions with pneumatic regulation.

  • Two-stage progressive.
  • Pneumatic valve.
  • Low NOx emissions.
Technical data
Fuel
Natural Gas
Operation
Pneumatic Modulation
Minimum Thermal Power (kW) to ErP
60
Maximum Thermal Power (kW) to ErP
205
Min flow rate (Sm³/H)
6.3
Max flow rate (Sm³/H)
21.7
Electric power supply type
AC
No. of Phases
1N
Power Supply Voltage (V)
230
Power Supply Frequency (Hz)
50/60
Fan Motor Power (kW)
0.2
Weight without packaging (kg)
17
Weight with packaging (kg)
18
Width (mm)
780
Depth (mm)
370
Height (mm)
410
Technical Descriptions
Gas burner compliant with European standard EN676. Pneumatic operation at two progressive stages.
Continuous modulation operation by installing P.I.D. controller in the control panel (to be ordered separately with modulation probe).
Modulation ratio 1:3.
Gas burner with low NOx and CO emissions in accordance with European standard EN676: class 3.
Regulating combustion air and blast-pipe.
Combustion air intake with throttle damper. Air flow adjustment with electric servomotor.
Fully closing air damper on shutdown to avoid loss of heat through the chimney.
Maintenance facilitated by the possibility of removing the combustion head without having to remove the burner from the boiler.
Sliding boiler coupling flange to adapt the blast-pipe to the various types of boilers.
Gas train CE version consisting of valve operation and safety pneumatically driven , minimum pressure switch , pressure regulator and gas filter
Possibility to choose gas train with valve tightness control.
Fail proof connectors for burner/gas train connection
Gas train exit: high.
Sound-proof plastic protective cover.
Flame detection by ionisation electrode with connector for micro amp meter.
7-pole socket for burner electric and thermostatic supply.
4-pole socket for second stage control or for the connection of the PID electronic regulator.
Electric protection rating:
Documents
Public documents
Type summary
Revision
Publish Date
Languages
Technical Sheet
1.0
16/07/2020
Use and maintenance manual
201003
 
Use and maintenance manual
201003
 
Use and maintenance manual
201003
 
Use and maintenance manual
201003
 
Statement of the manufacturer
202001
 
Statement of the manufacturer
202001
 
Certificate of conformity
201903
 
Certificate of conformity
201903
 
Reserved documents
Operating range

This product is part of the range BTG LX

Discover the entire series
Login
Cookies help us deliver our services. Using these services, you agree to the use of cookies on our part. Info